To monitor oxygen level in Nitrogen Gas Generator we required to install an Oxygen Gas Analyzer. This Analyser will be digital type mounted in Control Panel. In case of high O2%, it will give signal on panel and in turn impure gas shall be vented to atmosphere through vent valve provided in our system.
Sr. No | Descriptions | Details |
1. | Make | Nucon Engineers |
2. | Range | 0-30% |
3. | Display | Digital |
4. | Resolution | 0.1% |
5. | Sensor | Galvanic type made by citicell-USA |
6. | Power | 230 V AC |
7. | Alarm | 230 V AC, NO/NC |
8. | Recorder Output | 4-20mA |